9 Commits

Author SHA1 Message Date
794b27b8c6 Merge pull request 'documentation' (#7) from documentation into master
All checks were successful
CI/CD Pipeline / test (push) Successful in 33s
CI/CD Pipeline / build (push) Successful in 1m42s
CI/CD Pipeline / release (push) Has been skipped
Reviewed-on: #7
2025-12-26 22:02:46 -07:00
27e8987831 removed the temporary example slang scripts from the root directory
All checks were successful
CI/CD Pipeline / test (pull_request) Successful in 34s
CI/CD Pipeline / build (pull_request) Has been skipped
CI/CD Pipeline / release (pull_request) Has been skipped
2025-12-26 22:00:28 -07:00
0fdceac22c changed markdown tags from slang to rust 2025-12-26 21:57:11 -07:00
85f8b136e1 Update markdown tags to use rust instead of mips 2025-12-26 21:56:21 -07:00
c91086157a Added documentation for various language features and in-game functions. Added example scripts 2025-12-26 21:55:36 -07:00
6bee591484 Merge pull request 'Added stationpedia docs back into the game patches' (#6) from docs-fix into master
All checks were successful
CI/CD Pipeline / test (push) Successful in 33s
CI/CD Pipeline / build (push) Successful in 1m44s
CI/CD Pipeline / release (push) Successful in 5s
Reviewed-on: #6
2025-12-26 16:20:16 -07:00
c3c14cec23 Added stationpedia docs back into the game patches
All checks were successful
CI/CD Pipeline / test (pull_request) Successful in 33s
CI/CD Pipeline / build (pull_request) Has been skipped
CI/CD Pipeline / release (pull_request) Has been skipped
2025-12-26 16:18:24 -07:00
4e885847a8 Merge pull request 'Remove MOD from Plugin.cs which fixed networking' (#5) from slp-removal into master
All checks were successful
CI/CD Pipeline / test (push) Successful in 34s
CI/CD Pipeline / build (push) Successful in 1m43s
CI/CD Pipeline / release (push) Successful in 5s
Reviewed-on: #5
2025-12-24 22:28:51 -07:00
0ca6b27a11 Remove MOD from Plugin.cs which fixed networking
All checks were successful
CI/CD Pipeline / build (pull_request) Has been skipped
CI/CD Pipeline / release (pull_request) Has been skipped
CI/CD Pipeline / test (pull_request) Successful in 34s
2025-12-24 22:27:43 -07:00
13 changed files with 1070 additions and 152 deletions

View File

@@ -1,5 +1,14 @@
# Changelog
[0.4.4]
- Added Stationpedia docs back after removing all harmony patches from the mod
[0.4.3]
- Removed references to the `Mod` class from SLP. This was the root of the multiplayer
connectivity issues. Multiplayer should now work with Slang installed.
[0.4.2]
- Removed all harmony patches as most functionality as been added into the

View File

@@ -2,7 +2,7 @@
<ModMetadata xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<Name>Slang</Name>
<Author>JoeDiertay</Author>
<Version>0.4.2</Version>
<Version>0.4.4</Version>
<Description>
[h1]Slang: High-Level Programming for Stationeers[/h1]

View File

@@ -1,30 +1,45 @@
# Stationeers Language (slang)
# Slang Language Documentation
This is an ambitious attempt at creating:
Slang is a high-level programming language that compiles to IC10 assembly for [Stationeers](https://store.steampowered.com/app/544550/Stationeers/).
It provides a familiar C-like syntax while targeting the limited instruction set
of in-game IC10.
- A new programming language (slang)
- A compiler to translate slang -> IC10
- A mod to allow direct input of slang in the in-game script editor to
automatically compile to IC10 before running
## Quick Links
This project currently outputs 3 files:
- [Getting Started](docs/getting-started.md) - Installation and first program
- [Language Reference](docs/language-reference.md) - Complete syntax guide
- [Built-in Functions](docs/builtins.md) - System calls and math functions
- [Examples](docs/examples.md) - Real-world code samples
- A Linux CLI
- A Windows CLI
- A Windows FFI dll
- Contains a single function: `compile_from_string`
## Overview
The aim of this project is to lower the amount of time it takes to code simple
scripts in Stationeers so you can get back to engineering atmospherics or
whatever you are working on. This project is NOT meant to fully replace IC10.
Obviously hand-coded assembly written by an experienced programmer is more
optimized and smaller than something that a C compiler will spit out. This is
the same way. It WILL produce valid IC10, but for large complicated projects it
might produce over the allowed limit of lines the in-game editor supports.
Slang aims to reduce the time spent writing IC10 assembly by providing:
Current Unknowns
- **Familiar syntax** - C-like declarations, control flow, and expressions
- **Device abstraction** - Named device bindings with property access
- **Automatic register allocation** - No manual register management
- **Built-in functions** - Math operations and device I/O as function calls
- **Temperature literals** - Native support for Celsius, Fahrenheit, and Kelvin
- Should I support a configurable script line length in-game to allow larger
scripts to be saved?
- Should compilation be "behind the scenes" (in game editor will ALWAYS be what
you put in. IC10 will be IC10, slang will be slang)
## Example
```rust
device gasSensor = "d0";
device airCon = "d1";
const TARGET_TEMP = 20c;
loop {
yield();
airCon.On = gasSensor.Temperature > TARGET_TEMP;
}
```
This compiles to IC10 that monitors temperature and controls an air
conditioner.
## Project Status
Slang is under active development. It may produce suboptimal code for complex programs.
It is not a replacement for IC10, for performance-critical or large scripts,
hand-written IC10 may still be preferred.

18
csharp_mod/Patches.cs Normal file
View File

@@ -0,0 +1,18 @@
namespace Slang;
using Assets.Scripts.UI;
using HarmonyLib;
[HarmonyPatch]
public static class SlangPatches
{
[HarmonyPatch(typeof(Stationpedia), nameof(Stationpedia.Regenerate))]
[HarmonyPostfix]
public static void Stationpedia_Regenerate()
{
foreach (var page in Marshal.GetSlangDocs())
{
Stationpedia.Register(page);
}
}
}

View File

@@ -1,7 +1,6 @@
using System.Text.RegularExpressions;
using BepInEx;
using HarmonyLib;
using LaunchPadBooster;
namespace Slang
{
@@ -41,9 +40,7 @@ namespace Slang
{
public const string PluginGuid = "com.biddydev.slang";
public const string PluginName = "Slang";
public const string PluginVersion = "0.4.2";
public static Mod MOD = new Mod(PluginName, PluginVersion);
public const string PluginVersion = "0.4.4";
private Harmony? _harmony;

302
docs/builtins.md Normal file
View File

@@ -0,0 +1,302 @@
# Built-in Functions
<!--toc:start-->
- [Built-in Functions](#built-in-functions)
- [System Functions](#system-functions)
- [`yield()`](#yield)
- [`sleep(ticks)`](#sleepticks)
- [`hash(prefabName)`](#hashprefabname)
- [Device I/O Functions](#device-io-functions)
- [Reading from Devices](#reading-from-devices)
- [Load from device](#load-from-device)
- [Load From Device Batched](#load-from-device-batched)
- [Load From Device Batched Named](#load-from-device-batched-named)
- [Load Slot](#load-slot)
- [Load Reagent](#load-reagent)
- [Writing to Devices](#writing-to-devices)
- [Set On Device](#set-on-device)
- [Set On Device Batched](#set-on-device-batched)
- [Set On Device Batched Named](#set-on-device-batched-named)
- [Set Slot](#set-slot)
- [Math Functions](#math-functions)
- [Trigonometric Functions](#trigonometric-functions)
- [Trig Example](#trig-example)
- [Rounding Functions](#rounding-functions)
- [Rounding Example](#rounding-example)
- [Other Math Functions](#other-math-functions)
- [Math Example](#math-example)
- [See Also](#see-also)
<!--toc:end-->
Slang provides built-in functions for device I/O and mathematical operations.
These map directly to IC10 instructions.
## System Functions
### `yield()`
Pauses execution for exactly one game tick.
```rust
yield();
```
**IC10:** `yield`
---
### `sleep(ticks)`
Pauses execution for the specified number of ticks.
```rust
sleep(10); // Sleep for 10 ticks
```
**IC10:** `sleep ticks`
---
### `hash(prefabName)`
Computes the in-game hash for a prefab name. The hash is computed at compile
time and no runtime code is generated.
```rust
const AC_HASH = hash("StructureAirConditioner");
```
**Note:** This is different from IC10's `hash` instruction, which computes the
hash at runtime.
```rust
setBatched(AC_HASH, "On", 0);
```
**IC10:** `sb -2087593337 On 0` (no hash computation at runtime)
---
## Device I/O Functions
### Reading from Devices
#### Load from device
`load(device, property)` / `l(device, property)`
Loads a property value from a device:
```rust
let temp = load(sensor, "Temperature");
let temp = l(sensor, "Temperature");
// Preferred: use dot notation
let temp = sensor.Temperature;
```
**IC10:** `l r? d? var`
---
#### Load From Device Batched
`loadBatched(deviceHash, property, batchMode)` / `lb(...)`
Loads a property from all devices matching a hash, aggregated by batch mode:
```rust
const SENSOR = hash("StructureGasSensor");
let avgTemp = loadBatched(SENSOR, "Temperature", "Average");
let maxTemp = lb(SENSOR, "Temperature", "Maximum");
```
**Batch Modes:** `"Average"`, `"Sum"`, `"Minimum"`, `"Maximum"`
**IC10:** `lb r? deviceHash logicType batchMode`
---
#### Load From Device Batched Named
`loadBatchedNamed(deviceHash, nameHash, property, batchMode)` / `lbn(...)`
Loads a property from devices matching both device hash and name hash:
```rust
const SENSOR_HASH = hash("StructureGasSensor");
const SENSOR_NAME_HASH = hash("Outdoor Gas Sensor");
let avgTemp = loadBatchedNamed(SENSOR_HASH, SENSOR_NAME_HASH, "Temperature", "Average");
let maxTemp = lbn(SENSOR_HASH, SENSOR_NAME_HASH, "Temperature", "Maximum");
```
**IC10:** `lbn r? deviceHash nameHash logicType batchMode`
**Note:** This function is useful when a script interfaces with a lot of
devices, as it allows for arbitrary device access without limited to the 6 `dx` pins.
---
#### Load Slot
`loadSlot(device, slotIndex, property)` / `ls(...)`
Loads a slot property from a device:
```rust
let occupied = loadSlot(sorter, 0, "Occupied");
let occupied = ls(sorter, 0, "Occupied");
```
**IC10:** `ls r? d? slotIndex logicSlotType`
---
#### Load Reagent
`loadReagent(device, reagentMode, reagentHash)` / `lr(...)`
Loads reagent information from a device:
```rust
let amount = loadReagent(furnace, "Contents", reagentHash);
let amount = lr(furnace, "Contents", reagentHash);
```
**IC10:** `lr r? d? reagentMode reagentHash`
---
### Writing to Devices
#### Set On Device
`set(device, property, value)` / `s(...)`
Sets a property on a device:
```rust
set(valve, "On", true);
s(valve, "On", true);
// Preferred: use dot notation
valve.On = true;
```
**IC10:** `s d? logicType r?`
---
#### Set On Device Batched
`setBatched(deviceHash, property, value)` / `sb(...)`
Sets a property on all devices matching a hash:
```rust
const LIGHT_HASH = hash("StructureWallLight");
setBatched(LIGHT_HASH, "On", true);
sb(LIGHT_HASH, "On", true);
```
**IC10:** `sb deviceHash logicType r?`
**Note:** This function is useful when a script interfaces with a lot of devices,
as it allows for arbitrary device access without limited to the 6 `dx` pins.
---
#### Set On Device Batched Named
`setBatchedNamed(deviceHash, nameHash, property, value)` / `sbn(...)`
Sets a property on devices matching both device hash and name hash:
```rust
const SENSOR_HASH = hash("StructureGasSensor");
const SENSOR_NAME_HASH = hash("Outdoor Gas Sensor");
setBatchedNamed(SENSOR_HASH, SENSOR_NAME_HASH, "On", true);
sbn(SENSOR_HASH, SENSOR_NAME_HASH, "On", true);
```
**IC10:** `sbn deviceHash nameHash logicType r?`
---
#### Set Slot
`setSlot(device, slotIndex, property, value)` / `ss(...)`
Sets a slot property on a device:
```rust
setSlot(sorter, 0, "Open", true);
ss(sorter, 0, "Open", true);
```
**IC10:** `ss d? slotIndex logicSlotType r?`
---
## Math Functions
All math functions accept numbers, variables, or expressions as arguments.
### Trigonometric Functions
| Function | Description | IC10 |
| ------------- | ---------------------------- | ------- |
| `sin(x)` | Sine of angle in radians | `sin` |
| `cos(x)` | Cosine of angle in radians | `cos` |
| `tan(x)` | Tangent of angle in radians | `tan` |
| `asin(x)` | Arc sine, returns radians | `asin` |
| `acos(x)` | Arc cosine, returns radians | `acos` |
| `atan(x)` | Arc tangent, returns radians | `atan` |
| `atan2(y, x)` | Two-argument arc tangent | `atan2` |
#### Trig Example
```rust
let angle = atan2(y, x);
let sineValue = sin(angle);
```
### Rounding Functions
| Function | Description | IC10 |
| ---------- | ----------------------------- | ------- |
| `ceil(x)` | Round up to nearest integer | `ceil` |
| `floor(x)` | Round down to nearest integer | `floor` |
| `trunc(x)` | Remove decimal portion | `trunc` |
| `abs(x)` | Absolute value | `abs` |
#### Rounding Example
```rust
let rounded = floor(3.7); // 3
let positive = abs(-5); // 5
```
### Other Math Functions
| Function | Description | IC10 |
| ----------- | ----------------------------- | ------ |
| `sqrt(x)` | Square root | `sqrt` |
| `log(x)` | Natural logarithm | `log` |
| `max(a, b)` | Maximum of two values | `max` |
| `min(a, b)` | Minimum of two values | `min` |
| `rand()` | Random number between 0 and 1 | `rand` |
#### Math Example
```rust
let root = sqrt(16); // 4
let bigger = max(a, b);
let randomVal = rand();
```
## See Also
- [Language Reference](language-reference.md) — Complete syntax guide
- [Examples](examples.md) — Real-world code samples

254
docs/examples.md Normal file
View File

@@ -0,0 +1,254 @@
# Examples
Real-world Slang programs demonstrating common patterns.
## Temperature Control
Basic thermostat that controls an air conditioner based on room temperature:
```rust
device ac = "db";
device roomGasSensor = "d0";
const TARGET_TEMP = 22c;
const HYSTERESIS = 1;
loop {
yield();
let temp = roomGasSensor.Temperature;
if (temp > TARGET_TEMP + HYSTERESIS) {
ac.On = true;
} else if (temp < TARGET_TEMP - HYSTERESIS) {
ac.On = false;
}
}
```
**Note:** The IC10 chip is assumed to be inserted in the air conditioner's IC slot.
---
## Two-Axis Solar Panel Tracking
Handles two-axis solar panel tracking based on the sun's position:
```rust
device sensor = "d0";
const H_PANELS = hash("StructureSolarPanelDual");
loop {
setBatched(H_PANELS, "Horizontal", sensor.Horizontal);
setBatched(H_PANELS, "Vertical", sensor.Vertical + 90);
yield();
}
```
**Note:** Assumes the daylight sensor is mounted with its port looking 90
degrees east of the solar panel's data port, an offset can be added on the
horizontal angle if needed.
---
## Day/Night Lighting
Controls grow lights during the day and ambient lights at night:
```rust
device greenhouseSensor = "d0";
const daylightSensor = hash("StructureDaylightSensor");
const growLight = hash("StructureGrowLight");
const wallLight = hash("StructureLightLong");
loop {
yield();
let solarAngle = lb(daylightSensor, "SolarAngle", "Average");
let isDaylight = solarAngle < 90;
sb(growLight, "On", isDaylight);
sb(wallLight, "On", !isDaylight);
}
```
---
## Pressure Relief Valve
Controls a volume pump based on pressure readings for emergency pressure relief:
```rust
device volumePump = "d0";
device pipeSensor = "d1";
const MAX_PRESSURE = 10_000;
const R = 8.314;
loop {
yield();
let pressure = pipeSensor.Pressure;
if (pressure > MAX_PRESSURE) {
// Use PV=nRT to calculate the amount of mols we need to move
// n = PV / RT
let molsToMove = (pressure - MAX_PRESSURE) *
pipeSensor.Volume / (R * pipeSensor.Temperature);
// V = nRT / P
let setting = molsToMove * R * pipeSensor.Temperature / pressure;
volumePump.Setting = setting;
volumePump.On = true;
} else {
volumePump.On = false;
}
}
```
---
## Greenhouse Environment Controller
Complete greenhouse control with pressure, temperature, and lighting:
```rust
device self = "db";
device emergencyRelief = "d0";
device greenhouseSensor = "d1";
device recycleValve = "d2";
const MAX_INTERIOR_PRESSURE = 80;
const MAX_INTERIOR_TEMP = 28c;
const MIN_INTERIOR_PRESSURE = 75;
const MIN_INTERIOR_TEMP = 25c;
const daylightSensor = 1076425094;
const growLight = hash("StructureGrowLight");
const wallLight = hash("StructureLightLong");
const lightRound = hash("StructureLightRound");
let shouldPurge = false;
loop {
yield();
let interiorPress = greenhouseSensor.Pressure;
let interiorTemp = greenhouseSensor.Temperature;
shouldPurge = (
interiorPress > MAX_INTERIOR_PRESSURE ||
interiorTemp > MAX_INTERIOR_TEMP
) || shouldPurge;
emergencyRelief.On = shouldPurge;
recycleValve.On = !shouldPurge;
if (
shouldPurge && (
interiorPress < MIN_INTERIOR_PRESSURE &&
interiorTemp < MIN_INTERIOR_TEMP
)
) {
shouldPurge = false;
}
let solarAngle = lb(daylightSensor, "SolarAngle", "Average");
let isDaylight = solarAngle < 90;
sb(growLight, "On", isDaylight);
sb(wallLight, "On", !isDaylight);
sb(lightRound, "On", !isDaylight);
}
```
---
## Advanced Furnace Pressure Control
Automates multi-furnace pump control based on dial setting for pressure target:
```rust
const FURNACE1 = 1234;
const DIAL1 = 1123;
const ANALYZER1 = 1223;
const FURNACE2 = 1235;
const DIAL2 = 1124;
const ANALYZER2 = 1224;
const FURNACE3 = 1236;
const DIAL3 = 1124;
const ANALYZER3 = 1225;
const R = 8.314;
fn handleFurnace(furnace, dial, analyzer) {
let pressure = furnace.Pressure;
let targetPressure = max(dial.Setting, 0.1) * 1000;
if (abs(targetPressure - pressure) <= 0.1) {
furnace.On = false;
return;
}
let molsToMove = max(furnace.TotalMoles, 1) * (
(targetPressure / pressure) - 1
);
// V = nRT / P
if (molsToMove > 0) {
// Calculate volume required
if (analyzer.Pressure == 0) {
// No more gas to add
furnace.On = false;
return;
}
let volume = molsToMove * R * analyzer.Temperature / analyzer.Pressure;
furnace.On = true;
furnace.SettingOutput = 0;
furnace.SettingInput = volume;
return;
}
// Calculate volume required
let volume = (-molsToMove) * R * furnace.Temperature / pressure;
furnace.On = true;
furnace.SettingInput = 0;
furnace.SettingOutput = volume;
return;
}
loop {
yield();
handleFurnace(FURNACE1, DIAL1, ANALYZER1);
handleFurnace(FURNACE2, DIAL2, ANALYZER2);
handleFurnace(FURNACE3, DIAL3, ANALYZER3);
}
```
**Note:** This example does not handle edge cases such as insufficient gas in
the input network or overfilling the furnace/pipe network.
---
## Common Patterns
### Waiting for a Condition
```rust
fn waitForDeviceToTurnOff(device) {
while (device.On) {
yield();
}
}
```
## See Also
- [Getting Started](getting-started.md) — First steps with Slang
- [Language Reference](language-reference.md) — Complete syntax guide
- [Built-in Functions](builtins.md) — System calls and math functions

99
docs/getting-started.md Normal file
View File

@@ -0,0 +1,99 @@
# Getting Started
<!--toc:start-->
- [Getting Started](#getting-started)
- [Program Structure](#program-structure)
- [The `yield()` Function](#the-yield-function)
- [Your First Program](#your-first-program)
- [Explanation](#explanation)
- [Comments](#comments)
- [See Also](#see-also)
<!--toc:end-->
This guide covers the basics of writing your first Slang program.
## Program Structure
A Slang program consists of top-level declarations and a main loop:
```rust
// Device declarations
device self = "db";
device sensor = "d0";
// Constants
const THRESHOLD = 100;
// Variables
let counter = 0;
// Main program loop
loop {
yield();
// Your logic here
}
```
## The `yield()` Function
IC10 programs run continuously. The `yield()` function pauses execution for one
game tick, preventing the script from consuming excessive resources.
**Important:** You should always include `yield()` in your main loop unless you
know what you're doing.
```rust
loop {
yield(); // Recommended!
// ...
}
```
## Your First Program
Here's a simple program that turns on a light when a gas sensor detects low
pressure:
```rust
device gasSensor = "d0";
device light = "d1";
const LOW_PRESSURE = 50;
loop {
yield();
light.On = gasSensor.Pressure < LOW_PRESSURE;
}
```
### Explanation
1. `device gasSensor = "d0"` — Binds the device at port `d0` to the name
`gasSensor`
2. `device light = "d1"` — Binds the device at port `d1` to the name `light`
3. `const LOW_PRESSURE = 50` — Defines a compile-time constant
4. `loop { ... }` — Creates an infinite loop
5. `yield()` — Pauses for one tick
6. `light.On = gasSensor.Pressure < LOW_PRESSURE` — Reads the pressure and sets
the light state
## Comments
Slang supports single-line comments and documentation comments:
```rust
// This is a regular comment
/// This is a documentation comment
/// It can span multiple lines
fn myFunction() {
// ...
}
```
## See Also
- [Language Reference](language-reference.md) — Complete syntax guide
- [Built-in Functions](builtins.md) — Available system calls
- [Examples](examples.md) — Real-world programs and patterns

339
docs/language-reference.md Normal file
View File

@@ -0,0 +1,339 @@
# Language Reference
<!--toc:start-->
- [Language Reference](#language-reference)
- [Literals](#literals)
- [Numbers](#numbers)
- [Temperature Literals](#temperature-literals)
- [Booleans](#booleans)
- [Strings](#strings)
- [Variables](#variables)
- [`let` - Mutable Variables](#let-mutable-variables)
- [`const` - Constants](#const-constants)
- [Device Declarations](#device-declarations)
- [Device Property Access](#device-property-access)
- [Device Property Assignment](#device-property-assignment)
- [Operators](#operators)
- [Arithmetic Operators](#arithmetic-operators)
- [Comparison Operators](#comparison-operators)
- [Logical Operators](#logical-operators)
- [Ternary Operator](#ternary-operator)
- [Operator Precedence](#operator-precedence)
- [Control Flow](#control-flow)
- [`if` / `else`](#if-and-else)
- [`loop`](#loop)
- [`while`](#while)
- [`break`](#break)
- [`continue`](#continue)
- [Functions](#functions)
- [Declaration](#declaration)
- [Invocation](#invocation)
- [Return Values](#return-values)
- [Parentheses for Grouping](#parentheses-for-grouping)
- [See Also](#see-also)
<!--toc:end-->
Complete syntax reference for the Slang programming language.
## Literals
### Numbers
Numbers can be integers or decimals. Underscores are allowed as visual
separators:
```rust
const integer = 42; // Integer
const decimal = 3.14; // Decimal
const million = 1_000_000; // Integer with separators
const decimalSeparators = 5_000.50; // Decimal with separators
```
### Temperature Literals
Append a unit suffix to specify temperature. Values are automatically converted
to Kelvin at compile time:
| Suffix | Unit | Example |
| ------ | ---------- | ------- |
| `c` | Celsius | `20c` |
| `f` | Fahrenheit | `68f` |
| `k` | Kelvin | `293k` |
```rust
const ROOM_TEMP = 20c; // Converts to 293.15 Kelvin
const FREEZING = 32f; // Converts to 273.15 Kelvin
const ABSOLUTE1 = 0k; // Already in Kelvin
const ABSOLUTE2 = 0; // Assumed to be in Kelvin
```
### Booleans
Booleans compile to integer values `1` and `0` in IC10.
```rust
device ac = "d0";
ac.Mode = false;
ac.On = true;
```
### Strings
Strings use double or single quotes. They are primarily used for prefab and
name hashes.
```rust
const AC_HASH = hash("StructureAirConditioner");
const AC_NAME_HASH = hash("Greenhouse Air Conditioner");
```
## Variables
### `let` Mutable Variables
Declares a variable that can be reassigned:
```rust
let counter = 0;
// ...
counter = counter + 1;
```
### `const` Constants
Declares a compile-time constant. Constants are inlined and do not consume
registers:
```rust
const MAX_PRESSURE = 10_000;
const DOOR_HASH = hash("StructureCompositeDoor");
```
Constants support the `hash()` function for compile-time hash computation.
## Device Declarations
The `device` keyword binds a device port or reference ID to a named variable:
```rust
device self = "db"; // IC housing, or device the IC is plugged into (eg. an AC)
device sensor = "d0"; // Device at port d0
device valve = "d1"; // Device at port d1
device ac1 = "$3FC"; // Device with reference ID $3FC (hexadecimal 1020)
device ac2 = "1020"; // Device with reference ID 1020 (decimal)
```
**Note:** Reference IDs can be found in-game using the Configuration cartridge.
### Device Property Access
Read device properties using dot notation:
```rust
let temp = sensor.Temperature;
let pressure = sensor.Pressure;
let isOn = valve.On;
```
### Device Property Assignment
Write to device properties using dot notation:
```rust
valve.On = true;
valve.Setting = 100;
```
## Operators
### Arithmetic Operators
| Operator | Description | Example |
| -------- | -------------- | -------- |
| `+` | Addition | `a + b` |
| `-` | Subtraction | `a - b` |
| `*` | Multiplication | `a * b` |
| `/` | Division | `a / b` |
| `%` | Modulo | `a % b` |
| `**` | Exponentiation | `a ** b` |
| `-` | Negation | `-a` |
### Comparison Operators
| Operator | Description | Example |
| -------- | --------------------- | -------- |
| `==` | Equal | `a == b` |
| `!=` | Not equal | `a != b` |
| `<` | Less than | `a < b` |
| `>` | Greater than | `a > b` |
| `<=` | Less than or equal | `a <= b` |
| `>=` | Greater than or equal | `a >= b` |
### Logical Operators
| Operator | Description | Example |
| -------- | ----------- | ---------- |
| `&&` | Logical AND | `a && b` |
| `\|\|` | Logical OR | `a \|\| b` |
| `!` | Logical NOT | `!a` |
### Ternary Operator
Conditional expressions using `?` and `:`:
```rust
let result = condition ? valueIfTrue : valueIfFalse;
```
### Operator Precedence
Operators are evaluated in the following order, from highest to lowest
precedence:
| Precedence | Operator(s) | Description |
| ---------- | ----------------- | -------------------------------- |
| 1 | `()` `.` | Grouping, Property access |
| 2 | `!` `-` | Logical NOT, Negation |
| 3 | `**` | Exponentiation |
| 4 | `*` `/` `%` | Multiplication, Division, Modulo |
| 5 | `+` `-` | Addition, Subtraction |
| 6 | `<` `<=` `>` `>=` | Comparison |
| 7 | `==` `!=` | Equality |
| 8 | `&&` | Logical AND |
| 9 | `\|\|` | Logical OR |
| 10 | `?:` | Ternary conditional |
| 11 | `=` | Assignment |
Use parentheses to override precedence:
```rust
let result = (20 + 10) * 5;
```
## Control Flow
### if and else
Conditional branching:
```rust
if (tank.Temperature > 30c) {
ac.On = true;
} else {
ac.On = false;
}
```
### `loop`
Infinite loop that runs until `break`:
```rust
loop {
yield();
// Loop body
if (condition) {
break; // Exit the loop
}
}
```
### `while`
Conditional loop that runs while the condition is true:
```rust
while (counter < 100) {
counter = counter + 1;
yield();
}
```
### `break`
Exits the current loop:
```rust
loop {
yield();
// ...
if (done) {
break;
}
}
```
### `continue`
Skips to the next iteration of the current loop:
```rust
loop {
yield();
if (shouldSkip) {
continue;
}
// This code is skipped when shouldSkip is true
// ...
}
```
## Functions
**Warning:** Functions are currently experimental and may produce suboptimal code.
### Declaration
```rust
fn functionName(arg1, arg2) {
// Function body
return arg1 + arg2;
}
```
### Invocation
```rust
let result = functionName(10, 20);
```
### Return Values
Use `return` to exit a function and optionally return a value:
```rust
fn calculate(x) {
if (x < 0) {
return 0; // Early return
}
return x * 2;
}
fn doWork() {
// No return value
return;
}
```
## Parentheses for Grouping
Use parentheses to control operator precedence:
```rust
let result = (a + b) * c;
let complex = (
temp > 0c &&
stress < 50 &&
(pressure < 10_000 || temp > 20c)
);
```
## See Also
- [Getting Started](getting-started.md) — First steps with Slang
- [Built-in Functions](builtins.md) — System calls and math functions
- [Examples](examples.md) — Real-world code samples

View File

@@ -930,7 +930,7 @@ checksum = "e3a9fe34e3e7a50316060351f37187a3f546bce95496156754b601a5fa71b76e"
[[package]]
name = "slang"
version = "0.4.2"
version = "0.4.3"
dependencies = [
"anyhow",
"clap",

View File

@@ -1,6 +1,6 @@
[package]
name = "slang"
version = "0.4.2"
version = "0.4.3"
edition = "2021"
[workspace]

View File

@@ -1,43 +0,0 @@
device self = "db";
device gasSensor = "d0";
device atmosAnal = "d1";
device atmosValve = "d2";
device atmosTank = "d3";
device atmosInlet = "d4";
atmosInlet.Lock = true;
atmosInlet.Mode = 1;
atmosValve.On = false;
atmosValve.Lock = true;
let isPumping = false;
let tempPressure = 0;
loop {
yield();
let temp = gasSensor.Temperature;
let pres = atmosAnal.Pressure;
let liqV = atmosAnal.VolumeOfLiquid;
let tempVol = atmosAnal.Volume;
let stress = 5_000 * liqV / tempVol;
tempPressure = isPumping ? 1_000 : 10_000;
let shouldTurnOnInlet = (
temp > 0c &&
pres < tempPressure &&
stress < 50
);
isPumping = (
!shouldTurnOnInlet &&
atmosTank.Pressure < 35_000 &&
atmosAnal.RatioPollutant == 0 &&
atmosAnal.RatioLiquidPollutant == 0 &&
atmosAnal.Pressure > 1_000
);
atmosValve.On = isPumping;
atmosInlet.On = shouldTurnOnInlet;
}

View File

@@ -1,72 +0,0 @@
/// Laree script V1
device self = "db";
device larre = "d0";
device exportChute = "d1";
const TOTAL_SLOTS = 19;
const EXPORT_CHUTE = 1;
const START_STATION = 2;
let currentIndex = 0;
/// Waits for the larre to be idle before continuing
fn waitForIdle() {
yield();
while (!larre.Idle) {
yield();
}
}
/// Instructs the Larre to go to the chute and deposit
/// what is currently in its arm
fn deposit() {
larre.Setting = EXPORT_CHUTE;
waitForIdle();
larre.Activate = true;
waitForIdle();
exportChute.Open = false;
}
/// This function is responsible for checking the plant under
/// the larre at this index, and harvesting if applicable
fn checkAndHarvest(currentIndex) {
if (currentIndex <= EXPORT_CHUTE || ls(larre, 255, "Seeding") < 1) {
return;
}
// harvest from this device
while (ls(larre, 255, "Mature")) {
yield();
larre.Activate = true;
}
let hasRemainingPlant = ls(larre, 255, "Occupied");
// move to the export chute
larre.Setting = EXPORT_CHUTE;
waitForIdle();
deposit();
if (hasRemainingPlant) {
deposit();
}
larre.Setting = currentIndex;
waitForIdle();
if (ls(larre, 0, "Occupied")) {
larre.Activate = true;
}
waitForIdle();
}
loop {
yield();
if (!larre.Idle) {
continue;
}
let newIndex = currentIndex + 1 > TOTAL_SLOTS ? START_STATION : currentIndex + 1;
checkAndHarvest(currentIndex);
larre.Setting = newIndex;
currentIndex = newIndex;
}